                   Instrumentation:  Industrial - Aerospace - R&D Testing

                    We design and manufacture a full line of temperature and pressure probes.

 

 

 

 

 

Instrumentation

 

 

 

 

 

 

 

Pitot Static Tubes

  • Probe is used in a fluid stream when the total and static pressure is to be measured at the same point.
  • These pressure measurements are sufficient with a known temperature when calculating flow velocity, weight flow rate, energy density and viscosity of the moving fluid. Temperature must be measured if not known.
  • A 1% accuracy is attainable when flow angle is within 5 degrees of parallel to tip.
  • Probe can be used in liquids at all velocities, and air and other gases up to mach. 0.5.
  • Where flow is not straight or direction is not known, this type of probe is not recommended and should be kept at least 5 diameters away from the side wall.
  • Pitot static probes are not affected by reynolds number except at very low velocities.

 

 